From the shop floor to ERP: software and automation
We work on the software side of automation projects: we connect what operators enter and what machines produce to work orders, stations and reports in EPROX ERP.
- KEOS terminal
- Field Gateway
- Read-only by default
Shop-floor data should reach the ERP without delay or retyping
When output, scrap and downtime are written on paper and entered later, data is late and error-prone. The road to Industry 4.0 starts with collecting shop-floor data instantly and accurately. At Eprom Yazılım ve Otomasyon we connect this data to EPROX ERP and feed planning, costing and quality reports with real data.
Shop-floor data capabilities
Capabilities available in EPROX ERP today.
KEOS operator terminal
Station, work order and operator on a touch screen; output, scrap and downtime entry.
Offline operation
If the network drops, the terminal keeps records and transfers them without duplicates when it reconnects.
Field Gateway
A gateway program at your site reads PLCs and devices via Modbus TCP and sends the data to the ERP.
Read-only by default
The gateway does not write to machines; it only reads. You stay in control of your line.
Field Monitoring
Live values refresh every few seconds; tag history is shown as charts and tables.
Record binding
A PLC counter is bound to a field on a station record; values are written with an audit trail.
Project steps
- 01
Discovery
We identify your machines, stations and the data to collect, on site.
- 02
Terminals and gateway
We install KEOS terminals and, if needed, the Field Gateway program.
- 03
Tags and binding
We define device tags and bind them to station and work order records in the ERP.
- 04
Monitoring and reports
We open the data up through Field Monitoring and production reports.
Which protocols are available?
The driver available in the Field Gateway today is Modbus TCP (plus a simulator for testing). Other protocols such as Siemens S7, OPC UA, MQTT or RS485 Modbus RTU are not available yet; if you need one, we assess it for your project.
Frequently asked questions
Do you change our PLC programs?
No. The Field Gateway is read-only by default; it does not write to machines or PLCs.
Can it be used without EPROX ERP?
The KEOS terminal and Field Gateway are part of EPROX ERP; collected data is processed into work orders, stations and reports in EPROX ERP.
What if my machine does not support Modbus TCP?
We first check your machine's connection options during discovery. Operator entry is always possible with the KEOS terminal; other protocols are assessed per project.
Let's connect your shop-floor data to ERP
Tell us what you need; together we will choose the right software and plan installation and training. Reach us by phone, WhatsApp or the form.